Summary for Test 2018-09-07-6-4
Test performed: ASTM D624-00-re12Project Information
Project Identifiers | Project ID: 212743 DEA: 030H26U4 EFIS: 0317000247 |
---|---|
DIST-CO-RTE-PM | 03-PLA-65-R5.0/R6.6 |
Award Date | 02/14/2018 |
Closeout Date | 10/21/2022 |
Work Description | NORTHBOUND WIDENING AND RAMP IMPROVEMENTS. |
Location Description | PLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 12/18/2017) |
Sample Information
Sample Taken Date | 09/07/2018 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2018 |
Sample type | Quality Assurance | A brief description of the sample | Bearing Pad |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kayla | Last name of sampler or witnessed by | Wallace |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Dynamic Rubber | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | CR55-021-18 |
---|---|---|---|
Material/Compound/Elastomer ID | NA | Samples Representing | 5 |
Description (size) | 5.75" x 18" x 20" | Comments | Unknown |
Description (Number of Shims) | 10 | Type of Bearing Pad | Steel |
Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Dynamic Rubber |
Batch Number | NA |
Test Details
DIME Sample ID: 2018-09-07-6
DIME Test ID: 2018-09-07-6-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2018-10-03
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: Brian
Date of test: 09/19/2018
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.06 in
Sample 1 Tear Strength: 233.3 lbf / in
Sample 2 Median Thickness: 0.059 in
Sample 2 Tear Strength: 237.3 lbf / in
Sample 3 Median Thickness: 0.059 in
Sample 3 Tear Strength: 220.3 lbf / in
UTM: no data
Median of the Tear Strength Values: 233.3 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Sample 1
Source: Partner Data Point File
Test graph for Sample 2
Source: Partner Data Point File
Test graph for Sample 3
Test was verified on 9/26/2018 ✔