Summary for Test 2018-08-17-10-2
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 213267 DEA: 04013584 EFIS: 0416000289 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-8.0/8.3,0.9/1.4 |
Award Date | 03/29/2018 |
Closeout Date | 12/30/2019 |
Work Description | Pier Retention |
Location Description | In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza |
QA Service Level | 1 (Verified on 05/01/2018) |
Sample Information
Sample Taken Date | 08/17/2018 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Department Acceptance | A brief description of the sample | Concerte Cylinder |
The quantity of what the sample constitutes | 22 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Chetan | Last name of sampler or witnessed by | Sihra |
Title of sampler | TED | Telephone number of sampler | 415-823-6360 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Central Concrete | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | YBI Observation Structure |
Material Information
Material Type | Concrete | The concrete mix design number | 4E01C5S1 |
---|---|---|---|
The truck number from where the sample was collected | 8184 | The batch plant ticket number from where the sample was collected | 18689891 |
Concrete batch plant | 30 | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Mix Truck | Where the material sample would have been placed if not sampled | Pier 2 Girder Seat |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2018-08-17-10
DIME Test ID: 2018-08-17-10-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-09-14
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 09/14/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 195486 lb
Maximum load on cylinder 2: 200058 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6937.0 psi
Compressive strength of cylinder 2: 7076.7 psi
Compressive strength (to nearest 10 psi): 7010 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 9/14/2018 ✔