Summary for Test 2018-08-29-12-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213152 DEA: 032F5904 EFIS: 0300020624 |
---|---|
DIST-CO-RTE-PM | 03-YUB,NEV-20-20.1/21.7, 0.0/0.1 |
Award Date | 05/21/2018 |
Closeout Date | 12/06/2021 |
Work Description | CURVE REALIGNMENT AND SHOULDER WIDENING |
Location Description | YUBA AND NEVADA COUNTIES NEAR SMARTSVILLE FROM 0.5 MILE WEST OF MCGANNEY LANE TO MOONEY FLAT ROAD |
QA Service Level | 1 (Verified on 04/24/2018) |
Sample Information
Sample Taken Date | 08/29/2018 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2018 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Morris |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rebar Tracy | Transportation Laboratory (TL) Number | C874432 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S25-131-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4073439 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 7 |
Diameter of Hoop | 4'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
Welding Company | CMC Rebar (Tracy) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-08-29-12
DIME Test ID: 2018-08-29-12-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-09-17
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/10/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #7/22mm | 0.6 | 59550 | 99250 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 9/10/2018 ✔