Summary for Test 2018-07-31-18-2

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 213152
DEA: 032F5904
EFIS: 0300020624
DIST-CO-RTE-PM03-YUB,NEV-20-20.1/21.7, 0.0/0.1
Award Date05/21/2018
Closeout Date12/06/2021
Work DescriptionCURVE REALIGNMENT AND SHOULDER WIDENING
Location DescriptionYUBA AND NEVADA COUNTIES NEAR SMARTSVILLE FROM 0.5 MILE WEST OF MCGANNEY LANE TO MOONEY FLAT ROAD
QA Service Level1 (Verified on 04/24/2018)

Sample Information

Sample Taken Date07/31/2018 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/03/2018
Sample typeQuality Assurance A brief description of the sampleFine concrete agg
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMcKeehan
Title of samplerMaterial Tester Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) NumberC778826
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-29-0006
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedstock pile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-07-31-18
DIME Test ID: 2018-07-31-18-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2018-08-30

Test Results


What test(s) are being run?: Fine durability only
Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 08/30/2018
Fine durability index: 79
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/30/2018