Summary for Test 2018-08-09-4-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212888
DEA: 07202124
EFIS: 0700020870
DIST-CO-RTE-PM07-LA-710-20.9/24.6
Award Date02/16/2018
Closeout Date05/04/2022
Work DescriptionPAVEMENT REHABILITATION AND BRIDGE WIDENING
Location DescriptionLOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING
QA Service Level1 (Verified on 03/29/2018)

Sample Information

Sample Taken Date08/09/2018 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/09/2018
Sample typeQuality Assurance A brief description of the sampleResistance welded hoops
The quantity of what the sample constitutes1005 From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerQA Inspector Telephone number of sampler7077918219
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL48-084-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)6503145703
Hoop Manufacturer Lot Number(s)1, 5, 7 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop4'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-08-09-4
DIME Test ID: 2018-08-09-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-08-22

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/14/2018
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
115#7/22mm0.65708095130Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/15/2018