Summary for Test 2018-08-07-1-2

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 213126
DEA: 051J6604
EFIS: 0051800009
DIST-CO-RTE-PM05-SB-192-8.0/12.5
Award Date01/09/2018
Closeout Date10/29/2020
Work DescriptionReplace bridges (3) and bridge rails (2)
Location DescriptionIn Santa Barbara County in and near Santa Barbara, Montecito, and Carpinteria.
QA Service Level1 (Verified on 05/14/2018)

Sample Information

Sample Taken Date08/07/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/07/2018
Sample typeVerification A brief description of the sampleATB 1-3/8 in
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byCarolina Last name of sampler or witnessed byMargarito
Title of samplerMETS Rep Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Eng Transportation Laboratory (TL) NumberC647238
Inspector Lot Number from the Transportation Laboratory (TL) FormL73-016-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size11
Nut Specification for Threaded BarA29 System ManufacturerWilliams Form
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)100786059
Nut Heat Number(s)73100031 Bar Lot NumberUnknown
Nut Lot Number36Y3D Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-08-07-1
DIME Test ID: 2018-08-07-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-08-20

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/13/2018
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
12A722 1-3/8\" Threaded Bar & NutL73-016-181.5816312413795911.80A722 Threaded Bar and NutBrian

General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/13/2018