Summary for Test 2018-01-04-4-3
Test performed: ASTM C109-11Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/04/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/04/2018 |
Sample type | Annual Source Testing | A brief description of the sample | Type IP |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | CM185806 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SRMG | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Cementitious | Brand | Salt River Materials Group |
---|---|---|---|
Mill | Clarkdale | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2018-01-04-4
DIME Test ID: 2018-01-04-4-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2018-08-03
Test Results
Will control cubes be used per ASTM C311?: no
Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 03/27/2018
Age of specimen: 7 days
The amount of flow (In percent): 111 %
The amount of water used (In percent): 49 %
Maximum load of 1st specimen (lb): 14295 lb
Maximum load of 2nd specimen (lb): 14856 lb
Maximum load of 3rd specimen (lb): 14332 lb
Compressive strength of 1st specimen (psi): 3574 psi
Compressive strength of 2nd specimen (psi): 3714 psi
Compressive strength of 3rd specimen (psi): 3583 psi
Average Compressive strength (to nearest 10 psi): 3620 psi
General comments (publicly viewable) (Max 1000 characters): 7 day break
Test was verified on 8/3/2018 ✔