Summary for Test 2018-05-15-29-9

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 212887
DEA: 024F79U4
DIST-CO-RTE-PM02-SHA-151-5.5/R5.8
Award Date01/29/2018
Closeout Date01/08/2019
Work DescriptionHMA/RHMA PAVING AND ADA SIDEWALK WORK.
Location DescriptionSHASTA COUNTY IN SHASTA LAKE CITY FROM PANCAKE HILL DRIVE TO LOCUST AVENUE
QA Service Level1 (Verified on 04/09/2018)

Sample Information

Sample Taken Date05/15/2018 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/15/2018
Sample typeVerification A brief description of the sampleLab-batched, 1/2-inch Type G Aggregate, Unreated
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byOrtiz
Title of samplerTester Telephone number of samplerUnknown
Laboratory sample identificationD77384 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTullis Inc, Northstate Asphalt, Redding CA Transportation Laboratory (TL) Number002178
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-11-S1 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::SHASTA RANCH AGGREGATES
The fabricator's/manufacturer's product name for the sampleL180451 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedLab-batched from untreated stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 18-11-S1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-15-29
DIME Test ID: 2018-05-15-29-9
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2018-08-02

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 06/14/2018
Bulk dry specific gravity: 2.639
Average uncompacted voids: 48.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/2/2018