Summary for Test 2018-07-18-21-1
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 212534 DEA: 010H4904 EFIS: 0117000229 |
---|---|
DIST-CO-RTE-PM | 01-HUM,HUM-101-29.4, 29.40 |
Award Date | 06/23/2017 |
Closeout Date | 01/04/2021 |
Work Description | Slide and roadway repairs |
Location Description | Not set |
QA Service Level | 1 (Verified on 07/24/2017) |
Sample Information
Sample Taken Date | 07/18/2018 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/17/2018 |
Sample type | Verification | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | unknown | From where was the sample collected | Job Site |
First name of sampler or witnessed by | s | Last name of sampler or witnessed by | sami |
Title of sampler | asr | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | 01 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 01 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | chute | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-07-18-21
DIME Test ID: 2018-07-18-21-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2018-08-08
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Leif Ayres
Date of test: 08/15/2018
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 93670 lb
Maximum load on cylinder 2: 98260 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 5 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3,313.4 psi
Compressive strength of cylinder 2: 3,475.8 psi
Compressive strength (to nearest 10 psi): 3390 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/1/2018 ✔