Summary for Test 2017-05-17-15-6

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 212886
DEA: 023H1204
DIST-CO-RTE-PM02-TEH-5-R0.0/R22.4
Award Date01/03/2018
Closeout Date02/06/2019
Work DescriptionCOLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR
Location DescriptionTEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date05/17/2017 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/05/2017
Sample typeVerification A brief description of the sampleLaboratory-Combined Untreated Virgin 3/4-inch Type A Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJoseph Last name of sampler or witnessed bySturges
Title of samplerPEI Tech Telephone number of samplerUnknown
Laboratory sample identificationD76918F Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTullis, Inc - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number851339
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::SHASTA RANCH AGGREGATES
The fabricator's/manufacturer's product name for the sampleCombined Virgin Aggregate The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile at the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design number17-04-S1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2017-05-17-15
DIME Test ID: 2017-05-17-15-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2018-07-13

Test Results


Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 05/05/2017
Grading designation: B
Percent loss after 100 revolutions: 3 %
Percent loss after 500 revolutions: 12 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/13/2018