Summary for Test 2018-07-09-3-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212574
DEA: 02368414
EFIS: 0215000066
DIST-CO-RTE-PM02-SHA-44-R4.6/R6.4
Award Date10/13/2017
Closeout Date11/24/2021
Work DescriptionCONSTRUCT OVERCROSSING, WIDEN WITH HMA AND AB, AND OVERLAY WITH HMA
Location DescriptionSHASTA COUNTY NEAR PALO CEDRO FROM CLOUGH CREEK BRIDGE TO 0.6 MILE WEST OF DESCHUTES ROAD UNDERCROSSING
QA Service Level1 (Verified on 07/28/2017)

Sample Information

Sample Taken Date07/09/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/09/2018
Sample typeQuality Assurance A brief description of the samplesize 14 epoxy coated rebar couplers
The quantity of what the sample constitutes25 From where was the sample collectedJob Site
First name of sampler or witnessed byEric Last name of sampler or witnessed byChaffee
Title of samplerSR Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarSplice Transportation Laboratory (TL) NumberC733276
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A615
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size14 Coupler ModelGrip Twist
Coating StandardsASTM A775 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)Grip Twist male A160392 Grip Twist female A1 Rebar Heat Number(s)201318, 201418, 471117,
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-07-09-3
DIME Test ID: 2018-07-09-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-07-18

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/10/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#14/43mm2.25022472499877necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/11/2018