Summary for Test 2018-05-25-10-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209694 DEA: 080J0704 EFIS: 0800000282 |
---|---|
DIST-CO-RTE-PM | 08-SBD-215-0.6/1.7 |
Award Date | 10/17/2017 |
Closeout Date | 04/23/2020 |
Work Description | (Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA. |
Location Description | Grade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60. |
QA Service Level | 1 (Verified on 12/11/2017) |
Sample Information
Sample Taken Date | 05/25/2018 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/31/2018 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | EDDY | Last name of sampler or witnessed by | SCOTT |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 975-0525 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Robertsons Redlands | Transportation Laboratory (TL) Number | 975-0525 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | BENT 2 MIDDLE COLUMM |
Structure name | BENT 2 MIDDLE COLUMM |
Material Information
Material Type | Concrete | The concrete mix design number | SC590B38 |
---|---|---|---|
The truck number from where the sample was collected | 1207 | The batch plant ticket number from where the sample was collected | 3733516 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | MYERS |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | BENT 2 MIDDLE COLUMM |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-05-25-10
DIME Test ID: 2018-05-25-10-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-07-01
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 06/22/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 106540 lb
Maximum load on cylinder 2: 103660 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3743.5 psi
Compressive strength of cylinder 2: 3642.3 psi
Compressive strength (to nearest 10 psi): 3690 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/28/2018 ✔