Summary for Test 2018-06-21-10-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211235
DEA: 054482U4
EFIS: 0500000543
DIST-CO-RTE-PM05-SB-101-2.2/3.3
Award Date06/20/2016
Closeout Date08/23/2021
Work DescriptionBUILD AND RECONSTRUCT BRIDGES, CONSTRUCT RAMPS AND FRONTAGE ROAD.
Location DescriptionSANTA BARBARA COUNTY IN CARPINTERIA FROM 0.2 MILE SOUTH OF CARPINTERIA CREEK BRIDGE TO FRANKLIN CREEK BRIDGE
QA Service Level1 (Verified on 07/27/2016)

Sample Information

Sample Taken Date06/21/2018 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/25/2018
Sample typeQuality Assurance A brief description of the sampleBarsplice Zap Screwlok Coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byS Last name of sampler or witnessed byHeredia
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNorth Coast Steel Barsplice Transportation Laboratory (TL) NumberC761561
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size7 Coupler ModelZap Screwlok Type 2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorNucor
Coupler Component Heat/Lot Number(s)A171693 Rebar Heat Number(s)SE17101199
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-06-21-10
DIME Test ID: 2018-06-21-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-07-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/25/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#7/22mm0.605686694777Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample