Summary for Test 2018-06-05-8-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211513
DEA: 120M4904
EFIS: 1212000090
DIST-CO-RTE-PM12-ORA-5-1.2/2.2
Award Date09/20/2016
Closeout Date01/09/2020
Work DescriptionWIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location DescriptionORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
QA Service Level1 (Verified on 11/03/2016)

Sample Information

Sample Taken Date06/05/2018 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/08/2018
Sample typeQuality Assurance A brief description of the sample Bar Lock Standard Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJesus Last name of sampler or witnessed byR
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Dayton Superior Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormC697254 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size9 Coupler Model Bar Lock Standard Couplers
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)159754 Rebar Heat Number(s)4072111
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-06-05-8
DIME Test ID: 2018-06-05-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-06-20

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/12/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#9/29mm1-0.00329011190111Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/13/2018