Summary for Test 2018-04-16-2-10

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209694
DEA: 080J0704
EFIS: 0800000282
DIST-CO-RTE-PM08-SBD-215-0.6/1.7
Award Date10/17/2017
Closeout Date04/23/2020
Work Description(Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA.
Location DescriptionGrade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60.
QA Service Level1 (Verified on 12/11/2017)

Sample Information

Sample Taken Date04/16/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/06/2018
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes16 From where was the sample collectedJob Site
First name of sampler or witnessed byTim Last name of sampler or witnessed byFlores
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau, BarSplice Transportation Laboratory (TL) NumberC750005 C750006 C750007 C750009
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5, 6, 11 Coupler ModelTaper GripTwist DBL BRL Zap ScrewLok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A170511 A163671 177527 A170858 A172036 Rebar Heat Number(s)5 65028758, 6 65029129, 11 65027567
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-04-16-2
DIME Test ID: 2018-04-16-2-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-06-15

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/07/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#6/19mm0.44-0.00164172994839Necking OkBrian

General comments (publicly viewable) (Max 1000 characters): Necking Ok
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/8/2018