Summary for Test 2018-04-25-16-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 211197 DEA: 072827U4 EFIS: 0714000204 |
---|---|
DIST-CO-RTE-PM | 07-LA-5,101-16.4,S0.0/25.9 |
Award Date | 05/12/2016 |
Closeout Date | 08/12/2020 |
Work Description | WIDEN SHOULDERS, INSTALL MIDWEST GUARDRAIL SYSTEM AND CRASH CUSHIONS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT VARIOUS LOCATIONS FROM ROUTE 5/60 SEPARATION TO 0.1 MILE WEST OF VENTURA BOULEVARD OVERCROSSING. |
QA Service Level | 1 (Verified on 06/21/2016) |
Sample Information
Sample Taken Date | 04/25/2018 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/04/2018 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | ADDIS | Last name of sampler or witnessed by | AMBAYE |
Title of sampler | SR | Telephone number of sampler | Unknown |
Laboratory sample identification | 981-1 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Associated Ready Mix | Transportation Laboratory (TL) Number | S LOC 47 1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | AUSTIN VAULT 16 INCH CIDH SB 101 VAN BUYS ON RAMP |
Structure name | AUSTIN VAULT 16 INCH CIDH SB 101 VAN BUYS ON RAMP |
Material Information
Material Type | Concrete | The concrete mix design number | NOT PROVIDED |
---|---|---|---|
The truck number from where the sample was collected | 467 | The batch plant ticket number from where the sample was collected | 5809746 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | PLANT |
A detailed description of where the material sample was collected | TRUCK | Where the material sample would have been placed if not sampled | AUSTIN VAULT 16 INCH CIDH SB 101 VAN BUYS ON RAMP |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-04-25-16
DIME Test ID: 2018-04-25-16-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-05-30
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 05/23/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 132430 lb
Maximum load on cylinder 2: 135260 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4,684.5 psi
Compressive strength of cylinder 2: 4,784.6 psi
Compressive strength (to nearest 10 psi): 4730 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/23/2018 ✔