Summary for Test 2018-05-14-18-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 212680
DEA: 024F5504
EFIS: 0213000005
DIST-CO-RTE-PM02-SIS-89-20.9 - 21.2
Award Date11/14/2017
Closeout Date05/15/2019
Work DescriptionBRIDGE REPLACEMENT WITH PRE-CAST I-GIRDER AND RECONSTRUCT HIGHWAY
Location DescriptionSISKIYOU COUNTY NEAR MCCLOUD FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF MUD CREEK BRIDGE
QA Service Level1 (Verified on 02/12/2018)

Sample Information

Sample Taken Date05/14/2018 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2018
Sample typeVerification A brief description of the sampleCold Feed
The quantity of what the sample constitutesJMF Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byAllegretto
Title of samplerPEI Telephone number of samplerUnknown
Laboratory sample identificationD77366A Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTullis, Northstate Asphalt, Redding, CA Transportation Laboratory (TL) Number853535
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057
The fabricator's/manufacturer's product name for the sampleCold Feed The fabricator/manufacturer designation for the sampleL170303
The plant numberUnknown A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 17-05-R1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-14-18
DIME Test ID: 2018-05-14-18-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-07-10

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 05/15/2018
Cumulative Mass RetainedCumulative Percent Passing
3392.7 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
194.0 grams94 %
607.0 grams82 %
1161 grams66 %
1465.0 grams57 %
184.9 grams37 %
298.2 grams24 %
363.2 grams17 %
408.1 grams12 %
437.6 grams9 %
455.5 grams6.7 %
grams
General comments (publicly viewable) (Max 1000 characters): JMF 17-05-R1 Cold Feed

Test was verified on 7/10/2018