Summary for Test 2018-05-07-2-3
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/07/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/08/2018 |
Sample type | Verification | A brief description of the sample | re test 2 A563-DH HDG nut |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-085-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
---|---|---|---|
Heat Number(s) | 166581 | Nut Mfg. Lot Number(s) | Dyson DDWC |
Washer Mfg. Lot Number(s) | n/a | Bolt Specification | n/a |
Bolt Length(s) | n/a | Nut Specification | A563-DH HDG |
Washer Specification | n/a | Finish | HDG |
Diameter/Size | 2" | Bolt Mfg. Lot Number | n/a |
Rocap Test Requirement(s) | none | Lubricant Requirements(s) | wax and dye |
Test Details
DIME Sample ID: 2018-05-07-2
DIME Test ID: 2018-05-07-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2018-05-21
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 05/11/2018
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: DYSON DDWC
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: 2H DH
Size: no data
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/14/2018 ✔