Summary for Test 2018-05-04-7-1

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 212618
DEA: 044G0564
EFIS: 0417000154
DIST-CO-RTE-PM04-ALA-680-M2.4/M12.4
Award Date11/16/2017
Closeout Date12/08/2022
Work DescriptionROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location DescriptionFREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/16/2017)

Sample Information

Sample Taken Date05/04/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/07/2018
Sample typeQuality Assurance A brief description of the samplePrestressing Strand
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byRick Last name of sampler or witnessed byBettencourt
Title of samplerQA Inspector Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCon-Fab Insteel Transportation Laboratory (TL) NumberC874430
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-061-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s) Number of CoilsUnknown
Group NumberUnknown Strand Diameter.375 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)16104059 Mfg. Lot Number(s)1201406140922
Manufacturer(s)Insteel Wire Products

Test Details

DIME Sample ID: 2018-05-04-7
DIME Test ID: 2018-05-04-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-05-18

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/11/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
11610405912014061409220.0862360421043281.81Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/11/2018