Summary for Test 2017-12-12-10-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 211162
DEA: 044G4504
EFIS: 0412000477
DIST-CO-RTE-PM04-SOL-780-7.07
Award Date02/01/2017
Closeout Date11/15/2019
Work DescriptionREPLACE BRIDGE TO PROVIDE STANDARD VERTICAL CLEARANCE
Location DescriptionLAUREL STREET OC
QA Service Level1 (Verified on 05/20/2016)

Sample Information

Sample Taken Date12/12/2017 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/03/2018
Sample typeAnnual Source Testing A brief description of the sampleCoarse PCC Aggregate
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byJolie Last name of sampler or witnessed bySchneider
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification18-0066 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCemex Kerlinger Transportation Laboratory (TL) NumberC872975
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0015::KERLINGER - RHODES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2017-12-12-10
DIME Test ID: 2017-12-12-10-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2018-05-10

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Phillip Montes
Date of test: 05/10/2018
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 2.4 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/10/2018