Summary for Test 2018-05-04-10-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 05/04/2018 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/04/2018 |
Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Fred | Last name of sampler or witnessed by | Saylor |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S377872-3 | Number of Coils | 1 |
Group Number | NA | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0520917 | Mfg. Lot Number(s) | Unknown |
Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2018-05-04-10
DIME Test ID: 2018-05-04-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-05-17
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 05/10/2018
UTM: 120KIP
Temperature: 72 f
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0522917 | S377872-3 | 0.214 | 60173 | 54244 | 28.3 | 1.72 | Fred |
2 | S0522917 | S377872-3 | 0.214 | 60260 | 27.9 | 1.71 | Fred | |
3 | S0522917 | S377872-3 | 0.214 | 60551 | 27.8 | 1.75 | Fred | |
4 | S0522917 | S377872-3 | 0.214 | 60536 | 27.6 | 1.73 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/10/2018 ✔