Summary for Test 2018-04-19-3-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date04/19/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/20/2018
Sample typeQuality Assurance A brief description of the sampleA325 MG Rocap Assemblies
The quantity of what the sample constitutes2 lots From where was the sample collectedSource
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerQA Telephone number of sampler9165247768
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSLSB Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL53-018-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0100662, TT0100663
Heat Number(s) Nut Mfg. Lot Number(s)26790-6214342302, 24891-166809
Washer Mfg. Lot Number(s)D4413, M4664 Bolt SpecificationF3125, A325
Bolt Length(s)2.5, 2.250 Nut SpecificationA563
Washer SpecificationF436 FinishB695
Diameter/Size7/8, 3/4 Bolt Mfg. Lot NumberBM0555, M4664
Rocap Test Requirement(s) Lubricant Requirements(s)Blue

Test Details

DIME Sample ID: 2018-04-19-3
DIME Test ID: 2018-04-19-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-05-09

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/25/2018
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
12A26790-62143423027/8\"70727314.61Nut Proof LoadFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 5/2/2018