Summary for Test 2018-04-19-1-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 04/19/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/20/2018 |
Sample type | Quality Assurance | A brief description of the sample | A490 Bolts |
The quantity of what the sample constitutes | 3 lots | From where was the sample collected | Source |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Johnston |
Title of sampler | QA | Telephone number of sampler | 9165247768 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SLSB | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L53-018-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0100659, TT0100660, TT0100661 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 27479-178004 | |
Washer Mfg. Lot Number(s) | 307768 | Bolt Specification | F3125, A490 |
Bolt Length(s) | 2.75", 3", 3.250 | Nut Specification | A563 |
Washer Specification | F436 | Finish | Black |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 752410, 043097, 041847 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-04-19-1
DIME Test ID: 2018-04-19-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-05-08
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/25/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3A | 041847 | 1\" | 98021 | 436 | 10 | A490 | Fred |
General comments (publicly viewable) (Max 1000 characters): A490
Test Graph
Source: Partner Data Point FileTest was verified on 5/1/2018 ✔