Summary for Test 2018-04-02-6-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 212886 DEA: 023H1204 |
---|---|
DIST-CO-RTE-PM | 02-TEH-5-R0.0/R22.4 |
Award Date | 01/03/2018 |
Closeout Date | 02/06/2019 |
Work Description | COLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR |
Location Description | TEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 04/02/2018 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/03/2018 |
Sample type | Department Acceptance | A brief description of the sample | 3/4-inch Type A HMA |
The quantity of what the sample constitutes | Production Start Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Allegretto |
Title of sampler | Lab Tech | Telephone number of sampler | Unknown |
Laboratory sample identification | 17-07-P07, D77310 | Linked DIME Sample ID | 2018-04-02-5 |
The fabricator/manufacturer/facility name | Tullis Inc - Northstate Asphalt - Redding, CA | Transportation Laboratory (TL) Number | 852090 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 1-01 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Not set |
Sublot number | Not set | HMA Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-04-02-6
DIME Test ID: 2018-04-02-6-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2018-04-09
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/03/2018
Method Performed: no data
Mass of container filled with water: 7374.0 grams
Mass of oven-dry sample in air for Sample 1: 2569.0 grams
Mass of container filled with the sample and water for Sample 1: 8913.0 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.492
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2018 ✔