Summary for Test 2018-03-20-8-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/20/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/28/2018 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Williams |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Ameron International | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 1373701 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | Unytite | |
Washer Mfg. Lot Number(s) | 305695 | Bolt Specification | A325 |
Bolt Length(s) | 5.5 | Nut Specification | A563 |
Washer Specification | F436 | Finish | F2329 |
Diameter/Size | 1 | Bolt Mfg. Lot Number | 761555 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue |
Test Details
DIME Sample ID: 2018-03-20-8
DIME Test ID: 2018-03-20-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-04-06
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/29/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1B | 761555 | 1\" | 90897 | 404.3 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 3/30/2018 ✔