Summary for Test 2018-03-13-3-5
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 03/13/2018 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/15/2018 |
Sample type | Quality Assurance | A brief description of the sample | 7/8 x 2-3/4 HS Bolt |
The quantity of what the sample constitutes | 132 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jeffrey | Last name of sampler or witnessed by | Sulka |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | St Louis Screw and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L81-008-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0099212 |
---|---|---|---|
Heat Number(s) | 10511330 | Nut Mfg. Lot Number(s) | 26476-6214342202 |
Washer Mfg. Lot Number(s) | D4413 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 2-3/4" | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | Galvanized |
Diameter/Size | 7/8 | Bolt Mfg. Lot Number | BM0557 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2018-03-13-3
DIME Test ID: 2018-03-13-3-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-03-27
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 03/19/2018
Sample No.: 3B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: BM0557
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 SL
Size: .875 in
Bolt Length: 2.75 in
Measurement Average: 3.76 mils
General comments (publicly viewable) (Max 1000 characters):