Summary for Test 2018-03-05-1-2
Test performed: ASTM A934-13Project Information
Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
---|---|
DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
Award Date | 12/22/2016 |
Closeout Date | Not set |
Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 01/31/2017) |
Sample Information
Sample Taken Date | 03/05/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/09/2018 |
Sample type | Quality Assurance | A brief description of the sample | Epoxy coated Nr.7 rebar hoop |
The quantity of what the sample constitutes | 800 | From where was the sample collected | Source |
First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Trasoras |
Title of sampler | AsstMETSRep | Telephone number of sampler | 323-594-6208 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Fletcher Coating | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L107-004-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 6502932402 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | Rebar Coating Specification | ASTM A934 | |
Rebar Size (#) | 7 | Rebar Coating Color | Purple |
Rebar Manufacturer | Gerdau | Rebar Coater | Fletcher Coating Company |
Rebar Powder Manufacturer | Unknown | Release Number | 1096 thru 1098 |
Quality Assurance Code | A93418B28R2S17G06 |
Test Details
DIME Sample ID: 2018-03-05-1
DIME Test ID: 2018-03-05-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Test Release Date: 2018-03-21
Test Results
Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 03/14/2018
Total Number of Holiday: 0
Total Length: 5
Holidays Per Linear Foot of Bar: 0
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: NA
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/14/2018 ✔