Summary for Test 2018-03-09-6-5

Test performed: CTM 670-December 2013

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/09/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/12/2018
Sample typeRecertification A brief description of the sample10 size 6 flash welded rebar
The quantity of what the sample constitutes10 From where was the sample collectedManufacturer
First name of sampler or witnessed byJames Last name of sampler or witnessed byDoe
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) Number836237
Inspector Lot Number from the Transportation Laboratory (TL) FormB358-017-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)591865
Hoop Manufacturer Lot Number(s)N/A Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerEvraz
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-03-09-6
DIME Test ID: 2018-03-09-6-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-04-24

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/14/2018
UTM: 400KIP
Temperature: 72 F
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1Break-1100#6/19mmMachine #66630, Small Diameter0.444281797311NECKING OKBrian

General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point File

Test was verified on 4/17/2018