Summary for Test 2018-02-22-10-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/22/2018 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/28/2018 |
Sample type | Recertification | A brief description of the sample | Resistance Butt Welded Hoops |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | QAI | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Etiwanda | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-044-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 6502868702 |
Hoop Manufacturer Lot Number(s) | N/A | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6 |
Diameter of Hoop | 5'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Gerdau |
Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-02-22-10
DIME Test ID: 2018-02-22-10-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-03-23
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/09/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | Cycle-3 | 100 | #6/19mm | Federal S102 | 0.44 | 42931 | 97570 | NECKING OK | Brian |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 3/16/2018 ✔