Summary for Test 2018-03-05-4-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209694 DEA: 080J0704 EFIS: 0800000282 |
---|---|
DIST-CO-RTE-PM | 08-SBD-215-0.6/1.7 |
Award Date | 10/17/2017 |
Closeout Date | 04/23/2020 |
Work Description | (Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA. |
Location Description | Grade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60. |
QA Service Level | 1 (Verified on 12/11/2017) |
Sample Information
Sample Taken Date | 03/05/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/09/2018 |
Sample type | Quality Assurance | A brief description of the sample | 8 - Flash Welded Hoops |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | QAI | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110 021-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 6502396002 |
Hoop Manufacturer Lot Number(s) | Lot 1 and Lot 6 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 8 |
Diameter of Hoop | 3'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Gerdau |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-03-05-4
DIME Test ID: 2018-03-05-4-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-03-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/09/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 6 | #8/25mm | 0.79 | 78350 | 99180 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 3/12/2018 ✔