Test 2018-02-12-1-1 (ASTM A775-07b-re14) Summary

Project Information
Project IdentifiersProject ID: 212577
DEA: 11408704
EFIS: 1112000017
DIST-CO-RTE-PM11-SD-8-9.0/15.3
Work DescriptionSLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL.
Location DescriptionSAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON
Sample Information
Sample Taken Date2/12/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/12/2018
Sample typeQuality Assurance A brief description of the sampleA775 Expoxy Coated rebar
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byRob Last name of sampler or witnessed byRAMOS
Title of samplerQA Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameDayton Superior Modesto Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS08-011-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)SE17102987
Rebar Epoxy Batch Number(s)7T96025849 Rebar Coating SpecificationASTM A775
Rebar Size (#)#6 Rebar Coating ColorGreen
Rebar ManufacturerNucor Rebar CoaterDayton Superior
Rebar Powder ManufacturerValspar Release Number1387825-2
Quality Assurance CodeUnknown
Test Details
DIME Sample ID: 2018-02-12-1
DIME Test ID: 2018-02-12-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2018-03-01
Test Results

Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 02/22/2018
Lower spec. limit LSL: 7
Upper spec. limit USL: 16
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: no data
First Bar Side 2 mean value: no data
Second Bar Side 1 mean value: 0
Second Bar Side 2 mean value: 0
First Bar Mean:0
Second Bar Mean:0
Total mean value:no data
General comments (publicly viewable) (Max 1000 characters): Samples Do Not Comply With Material Specifications for Workmanship.

Test was verified on 02/22/2018