Summary for Test 2018-01-31-17-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
Award Date | 11/05/2015 |
Closeout Date | 01/18/2022 |
Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 01/31/2018 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2018 |
Sample type | Quality Assurance | A brief description of the sample | Griptwist Couplers |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | R | Last name of sampler or witnessed by | Sinah |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Gerdau BarSplce | Transportation Laboratory (TL) Number | C |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #11 | Coupler Model | Grip Twist |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A170858 | Rebar Heat Number(s) | 6502630602 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-01-31-17
DIME Test ID: 2018-01-31-17-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-02-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/16/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | #11/36mm | 1.56 | 0 | 154209 | 98852 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/20/2018 ✔