Summary for Test 2018-01-31-17-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date01/31/2018 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/16/2018
Sample typeQuality Assurance A brief description of the sampleGriptwist Couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byR Last name of sampler or witnessed bySinah
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau BarSplce Transportation Laboratory (TL) NumberC
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size#11 Coupler ModelGrip Twist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A170858 Rebar Heat Number(s)6502630602
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-01-31-17
DIME Test ID: 2018-01-31-17-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-02-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/16/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#11/36mm1.56-0.00215314498169necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 2/20/2018