Summary for Test 2018-02-08-1-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 210040 DEA: 04297624 EFIS: 0400020581 COOP: 042558 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84-22.9/25.7 |
Award Date | 09/30/2015 |
Closeout Date | 03/12/2020 |
Work Description | WIDENING AND EXPRESSWAY UPGRADES |
Location Description | ON ROUTE 84, FROM RUBY HILL DRIVE TO NORTH OF CONCANNON BOULEVARD |
QA Service Level | 1 (Verified on 11/10/2015) |
Sample Information
Sample Taken Date | 02/08/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2018 |
Sample type | Quality Assurance | A brief description of the sample | Resistance Butt Welded Hoops |
The quantity of what the sample constitutes | 15 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Misssion City Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-105-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 400017 |
Hoop Manufacturer Lot Number(s) | 3 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 |
Diameter of Hoop | 2'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
Welding Company | Mission City Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-02-08-1
DIME Test ID: 2018-02-08-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-02-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/14/2018
UTM: 75KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 3 | #4/13mm | 0.2 | 19709 | 98540 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/14/2018 ✔