Summary for Test 2018-01-18-1-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/18/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/22/2018 |
Sample type | Recertification | A brief description of the sample | Resistance Butt Welded Hoops |
The quantity of what the sample constitutes | 15 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | ED | Last name of sampler or witnessed by | Fleming |
Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Mission City Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-101-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Retest |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 159817 |
Hoop Manufacturer Lot Number(s) | 3 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6 |
Diameter of Hoop | 2'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
Welding Company | Mission City Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-01-18-1
DIME Test ID: 2018-01-18-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-01-30
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/23/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | Break-2 | 100 | #6/19mm | Janda #18801 | 0.44 | 44340 | 100773 | NECKING OK | Brian |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 1/23/2018 ✔