Summary for Test 2018-01-15-4-2
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 01/15/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/16/2018 |
Sample type | Independent Assurance | A brief description of the sample | HRC 555 T-heads |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | IQA | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Etiwanda | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-013-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4069054 | Head Manufacturer Lot Number(s) | Lot 144 |
Rebar Size | #8 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | Nucor |
Head Manufacturer | CMC | Head Fabricator | CMC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2018-01-15-4
DIME Test ID: 2018-01-15-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-01-24
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/17/2018
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 144 | 0.79 | 74470 | 94270 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/17/2018 ✔