Summary for Test 2018-01-09-4-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R74.1/R78.6 |
Award Date | 04/05/2017 |
Closeout Date | 07/06/2021 |
Work Description | CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY |
Location Description | FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE |
QA Service Level | 1 (Verified on 07/10/2017) |
Sample Information
Sample Taken Date | 01/09/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/12/2018 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A416 seven wire uncoated steel strand |
The quantity of what the sample constitutes | 2 samples from each pack | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Cummings |
Title of sampler | QA | Telephone number of sampler | 916-718-7759 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Confab Shafter | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S29-003-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | 1201406140922, S800753-3 | Number of Coils | 2 |
Group Number | Strand Diameter | .375 in | |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | 16104059, S0288188 | Mfg. Lot Number(s) | Same as Pack number |
Manufacturer(s) | Sumiden Wire Insteel |
Test Details
DIME Sample ID: 2018-01-09-4
DIME Test ID: 2018-01-09-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-01-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/12/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 16104059 | 1201406140922 | 0.088 | 23411 | 20849 | 26.9 | 1.81 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/16/2018 ✔