Summary for Test 2017-12-20-2-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211784
DEA: 11085784
EFIS: 1100000064
DIST-CO-RTE-PM11-SD-163-4.1/4.9
Award Date06/16/2017
Closeout Date08/10/2021
Work DescriptionINTERCHANGE MODIFICATION AND OVERCROSSING WIDENING.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING
QA Service Level1 (Verified on 09/05/2017)

Sample Information

Sample Taken Date12/20/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/04/2018
Sample typeRecertification A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes1 lot From where was the sample collectedFabricator
First name of sampler or witnessed bygreg Last name of sampler or witnessed byjohnston
Title of samplerQA Telephone number of sampler9165247768
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rbar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL53-220-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4071355 4070468 4067791 4063303
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4 6 8 9
Diameter of Hoop2'0' 5'0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-12-20-2
DIME Test ID: 2017-12-20-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-01-31

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/08/2018
UTM: 400KIP
Temperature: 72 F
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1Cycle-4100#9/29mm119135591355NECKING OKFred

General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point File

Test was verified on 1/24/2018