Summary for Test 2018-01-01-1-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date01/01/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/01/2018
Sample typeQuality Control A brief description of the sampleUntreated three-quarter-inch
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed bya Last name of sampler or witnessed bya
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification3512 17-02-S1b Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSNC - Mustang Pit Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)MSHA ID 2602089
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2018-01-01-1
DIME Test ID: 2018-01-01-1-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-01-12

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 01/01/2018
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 64.1 %
Cumulative percent passing the 1/2 in. sieve: 2.2 %
Cumulative percent passing the 3/8 in. sieve: 1.4 %
Cumulative percent passing the 1/4 in. sieve: 1.3 %
Cumulative percent passing the #4 sieve: 1.1 %
Cumulative percent passing the #8 sieve: 0.9 %
Cumulative percent passing the #16 sieve: 0.9 %
Cumulative percent passing the #30 sieve: 0.9 %
Cumulative percent passing the #50 sieve: 0.9 %
Cumulative percent passing the #100 sieve: 0.9 %
Cumulative percent passing the #200 sieve: 0.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/5/2018