Summary for Test 2017-12-21-3-2
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 211504 DEA: 060N9904 EFIS: 0612000114 |
---|---|
DIST-CO-RTE-PM | 06-FRE,MAD-41U-33.1/33.4,0.0/0.3 |
Award Date | 10/13/2016 |
Closeout Date | 10/02/2019 |
Work Description | BRIDGE SCOUR MITIGATION, SEISMIC RETROFIT AND UPGRADE RAIL. |
Location Description | FRESNO AND MADERA COUNTIES NEAR FRESNO FROM 0.1 MILE NORTH OF PERRIN ROAD UNDERCROSSING TO 0.1 MILE SOUTH OF AVENUE 9 UNDERCROSSING |
QA Service Level | 1 (Verified on 10/05/2016) |
Sample Information
Sample Taken Date | 12/21/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/21/2017 |
Sample type | Quality Assurance | A brief description of the sample | 5/8 x 12 A449 HDG all thread |
The quantity of what the sample constitutes | 12 of 1052 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Leavitt |
Title of sampler | QA Inspector | Telephone number of sampler | 510 590-0116 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S28-388-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | DL1610509502 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | A449 |
Bolt Length(s) | 12" | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 5/8 | Bolt Mfg. Lot Number | 29947 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2017-12-21-3
DIME Test ID: 2017-12-21-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-01-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/03/2018
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1B | A449 All Thread Rod | 0.226 | 30344 | 134 | 134266 | 122285 | 27636 | A449 All Thread Rod |
General comments (publicly viewable) (Max 1000 characters): A449 All Thread Rod
Test Graph
Source: Partner Data Point FileTest was verified on 1/4/2018 ✔