Summary for Test 2017-12-13-27-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 212854
DEA: 07342101
EFIS: 0717000244
DIST-CO-RTE-PM07-LA-5-27.0/66.5
Award DateNot set
Closeout DateNot set
Work DescriptionEstablish standard vertical clearance.
Location DescriptionIn Los Angeles County, at various locations.
QA Service Level1 (Verified on 10/30/2017)

Sample Information

Sample Taken Date12/13/2017 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/19/2017
Sample typeInformational A brief description of the sample8x12 Steel Plate
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byChristopher Last name of sampler or witnessed byGlasscock
Title of samplerMaterials Representative Telephone number of sampler(925) 338-7347
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCollected at jobsite Transportation Laboratory (TL) NumberC939201
Inspector Lot Number from the Transportation Laboratory (TL) FormL104 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)Unknown
Material SpecificationA572 GradeUnknown
Thickness.375 .5 ShapePlate
Metal Foundry Manufacturer (Mill)Unknown Plate Dimension8x12

Test Details

DIME Sample ID: 2017-12-13-27
DIME Test ID: 2017-12-13-27-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Test Release Date: 2018-01-10

Test Results


Number of Samples: 6
Input Type: Calculated
Tester's full name: Fred
Date of test: 12/27/2017
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberWidth (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Total Elongation (%)Tested By
1N/A0.4970.2565401196755238.2Fred
2N/A0.4980.257408886733938.2Fred
3N/A0.4980.1897424306521938.3Fred
4N/A0.4980.1897423206479238.3Fred
5N/A0.4980.187762216604739Fred
6N/A0.4980.1877416366597836.7Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 1/3/2018