Summary for Test 2017-12-12-4-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212253
DEA: 010H0304
EFIS: 0117000087
DIST-CO-RTE-PM01-HUM-96-20.0/24.0, 0.83
Award Date02/22/2017
Closeout Date01/08/2019
Work DescriptionREPAIR SLIPOUT
Location DescriptionIN HUMBOLDT COUNTY NEAR WEITCHPEC FROM 3.0 MILES OF KLAMATH RIVER BRIDGE #04-0144 TO 0.6 MILE EAST OF WEITCHPEC ROAD
QA Service Level1 (Verified on 04/24/2017)

Sample Information

Sample Taken Date12/12/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/13/2017
Sample typeQuality Assurance A brief description of the sampleBar Lock Standard Couplers
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byMike Last name of sampler or witnessed byMcCracken
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau Nucor Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau Nucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5, 6 Coupler ModelBarlock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)6 149301, 149973, 5 148253 Rebar Heat Number(s)6 6502864802, 6502911202 5 6502875902,
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-12-12-4
DIME Test ID: 2017-12-12-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-12-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/14/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#6/19mm0.44-0.0044215395802Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 12/18/2017