Summary for Test 2017-11-21-4-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
| Award Date | 09/02/2011 |
| Closeout Date | Not set |
| Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
| Location Description | Port of Long Beach (District 7) |
| QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
| Sample Taken Date | 11/21/2017 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/28/2017 |
| Sample type | Independent Assurance | A brief description of the sample | A706 T-headed rebar |
| The quantity of what the sample constitutes | 4 bars | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | IQA Inspector | Telephone number of sampler | 510-693-3545 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | CMC Rbar | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4069447 | Head Manufacturer Lot Number(s) | 4069447 |
| Rebar Size | #11 | Headed Bar Model Name | HRC 555 |
| Size of Head | Full Size - 9x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
| Head Manufacturer | CMC HRC | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2017-11-21-4
DIME Test ID: 2017-11-21-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-12-08
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/01/2017
UTM: 400KIP
Temperature: 72 F
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 95 | 1.56 | 146180 | 93710 | Head Popped Off | Brian |
General comments (publicly viewable) (Max 1000 characters): Head Popped Off
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 12/1/2017 ✔