Summary for Test 2017-11-10-2-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 211513
DEA: 120M4904
EFIS: 1212000090
DIST-CO-RTE-PM12-ORA-5-1.2/2.2
Award Date09/20/2016
Closeout Date01/09/2020
Work DescriptionWIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location DescriptionORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
QA Service Level1 (Verified on 11/03/2016)

Sample Information

Sample Taken Date11/10/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2017
Sample typeQuality Assurance A brief description of the sample3/4 in A307 Galvanized Anchor Rod
The quantity of what the sample constitutes300 From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUlmer Industries Transportation Laboratory (TL) NumberC939725
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-210-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)278417 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF1554
Bolt Length(s)3' Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size3/4 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-11-10-2
DIME Test ID: 2017-11-10-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-11-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/15/2017
UTM: 400KIP
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AA307 A .75 x 44\" Stud Rod0.33424489108733205037116824A307 A Stud Rod

General comments (publicly viewable) (Max 1000 characters): A307 A Stud Rod
Test Graph
Source: Partner Data Point File

Test was verified on 11/16/2017