Summary for Test 2017-11-03-4-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Sample Information

Sample Taken Date11/03/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/08/2017
Sample typeQuality Assurance A brief description of the sample2 Ductile Iron Casting
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDSI Farrar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)J117
Part Number (s)68 19 172 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Farrar
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2017-11-03-4
DIME Test ID: 2017-11-03-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-11-16

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 11/09/2017
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1J1170.5050.2003625031069407.7Fred
2J1170.5050.2003621991079709.8Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 11/9/2017