Summary for Test 2017-11-03-4-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-37.2/42.4 |
Award Date | 11/16/2015 |
Closeout Date | 07/11/2022 |
Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
Location Description | IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA |
QA Service Level | 1 (Verified on 03/07/2016) |
Sample Information
Sample Taken Date | 11/03/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/08/2017 |
Sample type | Quality Assurance | A brief description of the sample | 2 Ductile Iron Casting |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | DSI Farrar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | J117 |
---|---|---|---|
Part Number (s) | 68 19 172 | Material Specification | A536 |
Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2017-11-03-4
DIME Test ID: 2017-11-03-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-11-16
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 11/09/2017
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | J117 | 0.505 | 0.2003 | 62503 | 106940 | 7.7 | Fred | |
2 | J117 | 0.505 | 0.2003 | 62199 | 107970 | 9.8 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 11/9/2017 ✔