Summary for Test 2017-10-31-2-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date10/31/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/03/2017
Sample typeQuality Assurance A brief description of the sampleHRC 500 Couplers
The quantity of what the sample constitutes1 lot From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameIntegrity Rebar Transportation Laboratory (TL) Number941303
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-200-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerNucor Intermediate Assembler or FabricatorUnknown
Rebar Size#7 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarHoop
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorIntegrity Rebar Placers
Coupler Component Heat/Lot Number(s)NF100886990 Rebar Heat Number(s)65022421
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-10-31-2
DIME Test ID: 2017-10-31-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-11-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/06/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#7/22mm0.605519091983Ok NeckingBrian

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 11/6/2017