Summary for Test 2014-01-15-7378029-3
Test performed: ASTM C231-10Project Information
Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
Award Date | 01/03/2013 |
Closeout Date | 09/07/2018 |
Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 01/15/2014 | Sample Unique Key | 7378029 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 5 Cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | Buffalo |
Title of sampler | Not set | Telephone number of sampler | (951) 662-6132 |
Laboratory sample identification | 2014-01-15-0737 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Vulcan Materials - Truck 428 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Concrete | The concrete mix design number | 103612F |
---|---|---|---|
The truck number from where the sample was collected | 428 | The batch plant ticket number from where the sample was collected | 100811 |
Concrete batch plant | 41951 | The fabricator/manufacturer designation for the sample | Vulcan Materials Company |
A detailed description of where the material sample was collected | 301 R Footing Station 10.22 | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-01-15-7378029
DIME Test ID: 2014-01-15-7378029-3
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: ASTM C231-10: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Test Release Date: 2014-02-03
Test Results
Is wet sieving required?: No
Input Type: Calculated
Tester's full name: Brandon Buffalo
Date of test: 01/15/2014
Air content: 2.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/3/2014 ✔