Summary for Test 2017-09-19-16-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
Project Identifiers | Project ID: 212794 DEA: 024F7804 EFIS: 0213000032 |
---|---|
DIST-CO-RTE-PM | 02-SHA,LAS,PLU,SHA,SIS,TRI-5-22087-25.7 |
Award Date | 12/20/2018 |
Closeout Date | 10/20/2021 |
Work Description | CMS SIGNS IN SHASTA COUNTY |
Location Description | IN BUTTE, LASSEN, PLUMAS, SHASTA, SISKIYOU AND TRINITY COUNTIES IN VARIOUS LOCATIONS. |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 09/19/2017 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/10/2017 |
Sample type | Quality Control | A brief description of the sample | Structure foundation |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Mifkovic |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 17SOIL-0289 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C875110 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RC-17-001 |
Where the material sample would have been placed if not sampled | 0 to 5 ft |
Test Details
DIME Sample ID: 2017-09-19-16
DIME Test ID: 2017-09-19-16-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-10-18
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 10/18/2017
Total mass of material in the sample: 6410 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 47 grams
Cumulative mass retained on the 1/2 in. sieve: 48 grams
Cumulative mass retained on the 3/8 in. sieve: 46 grams
Cumulative mass retained on the #4 sieve: 155 grams
Cumulative mass retained on the #8 sieve: 65 grams
Total sample mass passing the #4 sieve: 1325 grams
Total mass of fine material in the sample: 659 grams
Cumulative mass retained on the pan: 592 grams
Total cumulative mass of coarse aggregate: 296 grams
Total cumulative mass of fine aggregate: 657 grams
Sum of coarse and fine aggregate: 1621
Percentage of coarse material: 18 %
Percentage of fine material: 82 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 94 %
Cumulative percent passing the 3/8 in. sieve: 91 %
Cumulative percent passing the #4 sieve: 82 %
Cumulative percent passing the #8 sieve: 74 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/18/2017 ✔