Summary for Test 2017-09-26-2-6

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/26/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/26/2017
Sample typeAnnual Source Testing A brief description of the sampleType I/II
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationCM175721 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNevada Cement Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandNevada Cement
MillFernley Nevada Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2017-09-26-2
DIME Test ID: 2017-09-26-2-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2018-08-08

Test Results


Input Type: Calculated
Tester's full name: Stephen Donnelly
Date of test: 10/13/2017
Type of Water Used: Potable
Initial time of setting: 120 min
Final time of setting: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/8/2018