Summary for Test 2017-07-19-1-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 212307
DEA: 044J6004
EFIS: 0415000370
DIST-CO-RTE-PM04-MRN-1,37&101-Var
Award Date06/02/2017
Closeout Date09/07/2022
Work DescriptionPLACE POLYESTER CONCRETE AND REPLACE JOINT SEALS.
Location DescriptionMARIN COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/19/2019)

Sample Information

Sample Taken Date07/19/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/19/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1065024
Batch number1065024 Mix number1065024

Test Details

DIME Sample ID: 2017-07-19-1
DIME Test ID: 2017-07-19-1-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-10-06

Test Results


Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 10/06/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 108 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.07
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 55 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3200 psi
Styrene ASTM D 2369 40% to 50 %: 47 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 595 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.5 grams
General comments (publicly viewable) (Max 1000 characters): Accepted QC Bond Test Result from Supplier.

Test was verified on 10/6/2017